❤ Add to collection

KCS2000 Micro Data Center

Pre-configured, self-contained solution that offers the efficiency, economy, interoperability, and control to implement an exceptional infrastructure strategy

3500.00
¥3499.00
¥3499.00
¥3499.00
Weight:0.00KG
Quantity:
(Inventory99999)
Buy Now!
Add to cart
Description

Pre-configured, self-contained solution that offers the efficiency, economy, interoperability, and control to implement an exceptional infrastructure strategy


1.System Definition

MDC (Micro Data Center) is positioned at the edge data computing industry, focusing on several main functions such as Ethernet services, cloud storage services, data-transfer services, online stream services, and block chain. There are several problems and perplexities in the current development of MDC, such as: diversification of equipment matching, non-standardization, complicated product  linking  methods, low stability, and limited professional requirements, complex wiring and difficult maintenance. Kotohira launched the KCS series MDC micro smart data center at the right time to solve many of the above problems, improving MDC operation safer, cable connection easier, so that a non-professional personnel can operate.


2. System Features

Kotohira KCS system application characteristics mainly reflected in: High system Integration, Centralize Communication Connection, Security Strategy Design brings high reliability. Smart Wiring to avoid single point of failure, rapid deployment, standardized design and overall supply chain bring strong compatibility, easy maintenance, remote monitoring and remote service more accurate and fast.

1) High Integration

  • KCS configurated the all-in-one integrated cabinet contains ATS, smart power distribution system, environmental monitoring system, precision cooling, temperature  and  humidity  control, smoke  detection  and fire-extinguisher, door access control detection etc. This design highly saves space and provides complete solution to end users.

2) Network Connection 

In the MDC system, wiring of product communication is always a big troublesome problem. such as:

  • Equipment comes from different suppliers resulting in different communication protocols. This will result in time-consuming on protocol conversions and meke product and services unsustainable.

  • Traditional RS485 connection method brings many hidden dangers to operation and maintenance.

  • JCS system adopts the network link better solve the above problems,even non-professional personnel can operate and use.

3) Security Design

  • All communication ports in the MDC system are electrically isolated for higher safety.

  • Provide encrypted SSL through HTTP, SNMP, SSH and other network protocols, remote control more secure and reliable .

  • Adopts dual bus-line architecture to provide redundant power supply for servers and IT equipment.

  • Provides multiple architectures to achieve N, 2N, N+1 redundant configurations .

  • Optional static transfer switch can ensure the reliability of the critical single power load.

4) Smart Wiring to Avoid Single Point Failure

  • KCS system adopts AC and DC busbar and network busbar to avoid single point of failure. 

  • Environmental monitoring system data collection can be completed by using the JEMS200 network adapter SNMP integrated monitoring and management module or the sensor port of the intelligent PDU to simplify sensor connections.

5) Standardized Structure

  • The standardization of products will bring safety, higher reliability, and easier maintenance. Therefore, whether the suppliers has the overall   ability of product development, manufacturing, and service capabilities if quite critical. Jeidar produces all key equipment in the Micro Data Center system, such as: UPS, intelligent power distribution ( PDC), precision air conditioning (AC) system, intelligent PDU, environmental  monitoring system ( EMS), and intelligent static/automatic transfer switch (ATS/STS). Which minimum the product cost and increase the ability to help users to manage the after-sale service and maintenance. 


3. Application 

Kotohira KCS system is mainly used in edge computing data centers and small data  centers, such as the financial securities, government, education, medical  care, ISP operators, and small and medium enterprises. with features of simple design, fast deployment, strong adaptability & pre-configurate. Non-professionals can operate and use the system.

ModelJCS2210JCS2315JCS2420JCS2530JCS2630More
Rack Size (W*D*H)mm600*1200*2000600*1200*2000600*1200*2000600*1200*2000600*1200*2000Customized
Number of IT Racks12345<20
Usable  Space (Excl. battery)69U (UPS: N)104U (UPS: N)158U (UPS: N)200U (UPS: N)242U (UPS: N)/
ColorRAL9005RAL9005RAL9005RAL9005RAL9005customized
IP Protection LevelIP5XIP5XIP5XIP5XIP5Xcustomized
UPS RedundancyN/2N/N+1N/2N/N+1N/2N/N+1N/2N/N+1N/2N/N+1N/2N/N+1
Power Supply & Power Distribution
UPS Capacity10KVA15KVA20KVA30KVA30KVA<90kva
UPS ModelBH100L-RMBH150L31-RMMT200L33-RMMT300L33-RMMT300L33-RM/
Battery PackVRLA/Lithum-ionVRLA/Lithum-ionVRLA/Lithum-ionVRLA/Lithum-ionVRLA/Lithum-ionVRLA/Lithum-ion
Input Power1/1phase3/1phase3/3phase3/3phase3/3phase3/3phase
System Frequency50 or 60Hz50 or 60Hz50 or 60Hz50 or 60Hz50 or 60Hz50 or 60Hz
PDUBasic 16outlets + smart 16outletsBasic 16outlets + smart 16outletsBasic 16outlets + smart 16outletsBasic 16outlets + smart 16outletsBasic 16outlets + smart 16outletsBasic/Smart
Power Distribution Module (PDC)63A single phase80A  3/1phase80A  3/3phase80A  3/3phase100A  3/3phase/
Lightning ProtectionLevel 3, 20kA/2PLevel 3, 20kA/2PLevel 3, 20kALevel 3, 20kALevel 3, 20kALevel 3, 20kA
Maintenance BypassYesYesYesYesYesYes
Precision Cooling System
Cooling  Capacity8.6KW12.8KW12.8KW17.6KW21.2KW<90.1kw
Mount TypeRM-splitRM-splitIn-rowIn-rowIn-rowIn-row
Outdoor UnitIncludeIncludeIncludeIncludeIncludeInclude
RefrigerantR410AR410AR410AR410AR410AR410A
Environment Monitoring System
LCD Display10.1"10.1"10.1"10.1"10.1"10.1"
Remote AccessWebWebWebWebWebWeb
Report ProtocolSNMP/RS485-Modbus/CAN busSNMP/RS485-Modbus/CAN busSNMP/RS485-Modbus/CAN busSNMP/RS485-Modbus/CAN busSNMP/RS485-Modbus/CAN busSNMP/RS485-Modbus/CAN bus
UPS Mgmt.YesYesYesYesYesYes
PDU  Mgmt.Available for Smart PDUAvailable for Smart PDUAvailable for Smart PDUAvailable for Smart PDUAvailable for Smart PDUAvailable for Smart PDU
PDC  Mgmt.YesYesYesYesYesYes
Cooling  Mgmt.YesYesYesYesYesYes
Smoke SensorYesYesYesYesYesYes
Temp. & Humi. SensorYesYesYesYesYesYes
Water LeakageYesYesYesYesYesYes
 Access ControlRFID/Finger/PINRFID/Finger/PINRFID/Finger/PINRFID/Finger/PINRFID/Finger/PINRFID/Finger/PIN
Door SensorFront/RearFront/RearFront/RearFront/RearFront/RearFront/Rear
Fire Extinguish (Optional)FM200/Novec1230FM200/Novec1230FM200/Novec1230FM200/Novec1230FM200/Novec1230FM200/Novec1230
Video SurveillanceOptionalOptionalOptionalOptionalOptionalOptional
Static Transfer SwitchOptionalOptionalOptionalOptionalOptionalOptional