Contact Us!
Current Page:
Precision air conditioner
❤ Add to collection

Precision air conditioner

Rackmount and in row air conditioners, energy-saving

0.00
¥0.00
¥0.00
¥0.00
Weight:0.00KG
Quantity:
(Inventory99999)
Buy Now!
Add to cart
Description

Rackmount and in row air conditioners, energy-saving


Product Introduction

The cooling system occupies a very important position in the MDC system. In response to the characteristics and needs of the MDC, Kotohira has carefully created an innovative and energy-saving GentleAir series, which covers rack-mounted precision air conditioners and in row precision air conditioners. This series is suitable for modular data centers and form modular solutions


Product classification and capacity

 Rackmount Installation capacity: 3.5/5.9/8.6/12.8kw

 Top mount cooling capacity: 3.5kw

 In row cooling capacity: 5.6/12.8/17.6/21.2/25.1/31.1/40.9/51.2/65.7/76.8/90.1kw


Rack-mounted air conditioners features

 Frequency conversion compressor, adjustable cooling capacity, precise control of

internal temperature, avoid shortening the life of the compressor caused by frequent start and stop of the compressor.

 Dedicated precision air-conditioning control system, supports dynamic fault alarm and protection, monitoring  data upload and remote monitoring management.

 Rack-mounted modular structure and supports modular expansion

 R410A environmentally friendly refrigerant, green and no ozone layer damage.

 Copper pipes are connected by quick joints, supporting upper and lower connection.

 Adopt EC fans and dynamically adjust air volume

 The flat air outlet can be installed in any U position inside the cabinet.


In row air conditioners features

Dynamic energy-saving

EC fan with stepless speed regulation automatically match the air volume demand of the server

 Inverter compressor, cooling output automatically matches server thermal load changes

 Outdoor fan is driven by variable frequency stepless speed regulation, the wind speed is automatically adapted to the change of ambient temperature

 Electronic expansion valve control, automatically matching server thermal load changes

 The air supply temperature control function ensures that the server air intake temperature meets the design range, which is safe, reliable, energy-saving and environmentally friendly.

 Standard configuration includes 1 supply air temperature sensor and 1 return air temperature and humidity sensor, and 16 external temperature sensors are optional.

 37℃ return air temperature, 100% sensible heat rate design, energy saving and environmental protection.

 R410A environmentally friendly refrigerant.

Easy to install and maintain

 100% front and rear maintenance

 Support up and down connection, convenient for on-site pipeline layout, and can be installed with or without raised floors

 Built-in refrigerant pressure sensor and refrigerant temperature sensor, users can check the high pressure and low pressure of the system in real time, convenient for system problem diagnosis

 The return air temperature, liquid pipe temperature, subcooling degree, superheating degree of the refrigeration system and the speed percentage of the compressor and the outdoor fan. Facilitate equipment maintenance and operation monitoring to ensure reliable operation of equipment

 In order to ensure the stable and reliable operation of the refrigeration system, the refrigeration system of precision air-conditioning equipment is equipped with an oil separator as standard

 Optional Rotalock interface for the copper pipe interface, quick replacement after installation

 Independently controlled redundant fan system design, and supports plug-in replacement and maintenance

 Drawer designed electric control box convenient for the management and maintenance of the electric control components

 G4 air filter to meet the cleanliness of the computer room. Powerful, suitable for a variety of application situations

Powerful, suitable for a variety of application situations

 7-inch touch color display screen display temperature and humidity curves, graphically displaythe operating status of each component in the unit.

 Ability to store large-capacity fault alarm records, and the storage history alarm information is not less than 1000 pieces

 Rack-level size design, compatible with IT environment

 Standard air supply direction, horizontal front air supply, with hot and cold aisles, high efficiency and energy saving, optional horizontal side air supply, air flow evenly distributed on the front of the cabinet, for applications without sealed aisles

 The unit has casters and the height is adjustable.

 All series models support heating and humidification functions

 Standard depth is 1100mm, optional 1200mm.



GentleAir soft wind series rack-mounted air-cooled type technical parameters

Indoor unit model

JS-003KA

JS-005KA

JS-008KA

JS-012KA

Total Cooling Capacity-kW

3.5

5.9

8.6

12.8

Sensible heat ratio-%

1

1

1

1

Air volume-m3/h

700

1100

1600

2400

Installation form

Rack-mount

Rack-mount

Rack-mount

Rack-mount

Input Power

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

Interface-mm

6/10

10/12

10/12

12/16

Drain pipe interface-mm

20

20

20

20

Width × Depth × Height-mm

483×750×175/4U

483×828×355/8U

483×828×445/10U

483×828×533/12U

Weight - kg

22

43

52

70

Refrigeration form

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Heating (optional)-kW

1.2

1.2

2.4

2.4

Full load current (cooling only)-A

13.5

15.2

21.6

18.0

Outdoor unit model

JKSF06AC

JKSF08AC

JKSF12AC

JKSF18AC

W× D × H-mm

898×340×606

820×420×790

820×420×790

820×455×1240

Outdoor unit weight-kg

35

38

50

77

Outdoor unit input power

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

380V/50-60Hz/3Ph

Outdoor unit full load current-A

12.6

13.2

19.6

16

Copper pipe interface-mm

6/10

10/12

10/12

10/12


GentleAir soft wind series rack-mounted air-cooled type technical parameters

Indoor unit model

JS-05RAY

JS-12RAY

JS-12RAY

JS-17RAY

JS-20RAY

JS-25RAY

Total Cooling Capacity-kW

5.6

7.6

12.8

17.6

21.2

25.1

Sensible heat ratio-%

1

1

1

1

1

1

Air volume-m3/h

2000

2250

2400

4500

4920

5000

Installation form

In Row

In Row

In Row

In Row

In Row

In Row

Input Power

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

Copper pipe interface-mm

10/12

10/12

12/16

16/16

16/16

16/22

Drain pipe interface-mm

20

20

20

20

20

20

Width × Depth × Height-mm

300×1200×2000

300×1200×2000

300×1200×2000

300×1200×2000

300×1200×2000

300×1200×2000

Weight - kg

210

213

233

253

258

260

Refrigeration form

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Heating (optional)-kW

3.0

3.0

3.0

6.0

6.0

6.0

Humidification (optional)-kg/h

1.5

1.5

1.5

1.5

1.5

1.5

Humidification (optional) inlet pipe interface

¾”G

¾”G

¾”G

¾”G

¾”G

¾”G

Full load current (excluding humidification)-A

28.2

37.3

48.7

27.0

26.7

27.9

Full load current (constant temperature and humidity)-A

33.3

42.4

53.8

32.1

31.8

33.0

Outdoor unit model

JKSF08AN

JKSF12AN

JKSF18AN

JKSF24AN

JKSF32AN

JKSF38AN

W× D × H-mm

880×420×790

820×420×790

800×420×1240

1407×990×689

1407×990×689

1407×990×695

Mounting foot height-mm

-

-

-

450

450

450

Outdoor unit weight-kg

28

40

67

105

110

120

Outdoor unit input power

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

220V/50-60Hz/1Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

Outdoor unit full load current-A

1.5

1.5

3.0

2.0

2.0

2.8

Copper pipe interface-mm

10/12

10/12

12/16

16/22

16/22

16/22


GentleAir soft wind series rack-mounted air-cooled type technical parameters

Indoor unit model

JS-30RAY

JS-40RAY

JS-50RAY

JS-65RAY

JS-75RAY

JS-90RAY

Total Cooling Capacity-kW

31.1

40.9

51.2

65.7

76.8

90.1

Sensible heat ratio-%

1

1

1

1

1

1

Air volume-m3/h

5800

8000

10000

12000

13500

16000

Installation form

In Row

In Row

In Row

In Row

In Row

In Row

Input Power

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

Copper pipe interface-mm

16/22

16/22

16/22

16/22

16/22

16/22

Drain pipe interface-mm

20

20

20

20

20

20

Width × Depth × Height-mm

300×1100×2000

600×1100×2000

600×1100×2000

600×1100×2000

900×1100×2000

900×1100×2000

Weight - kg

320

360

420

460

540

620

Refrigeration form

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Air-cooled compressor

Heating (optional)-kW

6.0

6.0

6.0

6.0

6.0

6.0

Humidification (optional)-kg/h

3

3

3

3

3

3

Humidification (optional) inlet pipe interface

¾”G

¾”G

¾”G

¾”G

¾”G

¾”G

Full load current (excluding humidification)-A

34.6

37.7

48.1

60.6

70.8

84.6

Full load current (constant temperature and humidity)-A

39.7

47.9

58.3

30.8

81.0

94.8

Outdoor unit model

JKSF42AN

JKSF52AN

JKSF62AN

JKSF85AN

JKSF85AN

2×JKSF52AN

W× D × H-mm

1607×1273×695

1607×1273×695

800×420×12402107×1273×689

2407×1273×695

2407×1273×695

2107×1273×689

Mounting foot height-mm

450

450

450

450

450

450

Outdoor unit weight-kg

130

150

160

230

150

160

Outdoor unit input power

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

380V/50-60Hz/3Ph

Outdoor unit full load current-A

2.8

4.0

4.0

5.6

4.0

4.0

Copper pipe interface-mm

22/28

22/28

22/28

22/28

22/28

22/28